| Status: |
Advanced registration for this seminar is now closed. A limited number of registrations will be accepted at the door. |
| Date: |
Friday, February 10, 2012 |
| Time: |
Registration & Continental Breakfast: 8:30 – 9:00 AM
Seminar: 9:00 AM – 5:00 PM (Lunch will be provided) |
| Location: |
Coast Coal Harbour Hotel
1180 West Hastings Street, Vancouver, BC
Meeting Room: Grouse Room (4th Floor)
** 3 minutes walk from Burrard Skytrain Station or 10 minutes walk from Waterfront (Expo or Millenium Line) Skytrain Station/Canada Line.
** Public parkade next to hotel. Hotel valet parking $21 per day.
This seminar is also being offered in Kelowna. |
| Instructor: |
Charlie F. Henville, P.Eng., President, Henville Consulting Inc. |
| Credit: |
7 Professional Development Hours (PDH) |
| Fee: |
APEGBC Members (until January 20, 2012): $415.00 + HST = $464.80
APEGBC Members (after January 20, 2012): $485.00 + HST = $543.20
Non-Members: $485.00 + HST = $543.20
MAPS Members (Member Advantage Program for Students): $242.50 + HST = $271.60 |
| Notes: |
Please bring a calculator to the session. |
| APEGBC Contact: |
Shirley Chow, Professional Development Coordinator
Email: schow@apeg.bc.ca
Phone: 604-412-4865
Toll-Free: 1-888-430-8035 ext. 4865 |
To avoid the cancellation of this seminar, please register before January 20, 2012.
Please register early as there is limited seating available. |
Assuming the attendee has a working knowledge of short circuit analysis of power systems, this course will describe how to apply and set overcurrent protection systems. Topics include applications of fuses, reclosers, and overcurrent relays to provide coordinated short circuit protection of radial distribution systems. This includes overcurrent protection of busses, transformers, lines and cables.
Topics will include:
Overview of grounding practices for distribution system neutrals (ungrounded, high, or low impedance grounded or solidly grounded)
Time/current characteristics of overcurrent protection devices
Time/current damage curves of conductors and transformers
Application and selection of fuses for protection of distribution systems
Discussion of measured quantities, phase, ground, or negative sequence currents
Selection and setting of circuit reclosers
Measuring principles of time and instantaneous overcurrent relays
Selection and setting of time and instantaneous overcurrent relays
Coordination of relays, fuses and reclosers with each other
Protection complications introduced by networked systems and/or distributed resources connected to traditional radial distribution systems
Techniques for “load blinding”
Relaying accuracy of current transformers
The short circuit computer program ASPEN OneLiner will be used as an example of a computer tool for protective device coordination. However this is not a training seminar on the use of ASPEN OneLiner.
Due to time limitations, protection of motors, and generators is not included. Also discussion of differential protection systems is not included. Previous participation in the APEGBC companion seminar “Short Circuit Analysis of Power Systems” would be helpful, but is not a prerequisite as long as the attendee has a working knowledge of short circuit analysis techniques.
Charlie Henville is a specialist in electric power system protection. After a thirty year career with BC Hydro, he retired in 2005 from the position of principal engineer. He now runs his own consulting company in power system protection. Charlie is well experienced in training engineers in power systems. He is adjunct faculty at the University of Wisconsin and the University of BC, and has presented training courses to working engineers world wide. He is a Fellow of the Institute of Electrical and Electronic Engineers, and a past recipient of APEGBC's President's Award for professional service. For a more detailed resume, please visit: http://www.henvilleconsulting.com .
- "Good speaker, takes time to explain, good knowledge base and experience. Open to new information and correction."
- “Excellent presenter. Made a potentially dry topic interesting, thanks to visible passion for it as well as good strong voice to complement slides. Thanks.”
- “Excellent speaker, encouraged questions and class participation. Very knowledgeable.”
- “Good speaker (volume and clarity). Good slideshow. Good on screen tools with flipchart backups.”
- "Very good instructor. Has a good knowledge of the industry."
- "The seminar content was excellent with many examples from utility."
- "Charlie is an excellent speaker/presenter. Everything was easy to follow, handouts and materials were clear, and the pace was good (not too slow, not too fast)."
Registered attendees unable to attend the event may designate a substitute, provided APEGBC receives written notification at least one business day prior to the event. Registration information for the substitute attendee should accompany the notice. If notice of cancellation of registration is received:
• 5 business days or more prior to the event, a refund will be processed
• Less than 5 business days prior to the event, no refunds apply
Substitute registrants are permitted up to the day of the seminar and member/non-member fees will be applied. The organizers reserve the right to cancel the event if less than the minimum required participants have registered. Liability limited to registration fee.

APEGBC is an AIBC/CES registered provider offering an AIBC-Accredited activity for 6.5 Core Learning Units.
© APEGBC |